Abstract

This paper proposes a new method of diagnosing 16.7 MeV high-energy pulsed gamma, named "scattering-absorbing method" . The ratio of the sensitivity of HEG to that of the LEG can reach 106 to 108 by this new method. The sensitivity of 16.7 MeV high-energy gamma ranges from 10-21 to 10-16 C·cm2. It's better than the traditional method which bases on the magnetic analyzer and Cherenkov detector on some aspects.

Figures

图1

图2

图3

References

[ 1 ] 叶玉云,陈涵德,何锡钧,等.纳秒级d-T聚变反应的16.7MeVγ测量[J].原子能科学技术,1996,30(2):127-133 link1

[ 2 ] Michael J M.The fusion diagnostic gamma experiment: a high - bandwidth fusion diagnostic of the national ignition facility [ J ] . Rev.Sci.Instrum., 1999 , 70 ( 1 ) :1226 -1228 link1

[ 3 ] Caldwell S E, Berggren R R.Observation of d -t fusion gamma rays (invited) [J].Rev.Sci.Instrum., 2003, 74(3) : 1837 -1841 link1

[ 4 ] John E, Brolley, Joseph S, et al.A gas Cerenkov detector for measuring 16.7 -MeV gamma rays from the D( T,γ) 5He reaction [ R] .1983.LA -UR -83 -1864

[ 5 ] 吴治华,赵国庆,陆福全,等.原子核物理实验方法[M].北京:原子能出版社,1997

[ 6 ] Lerche R A, Phillion D W,Tietbohl G L,et al.25 ps neutron de- tector for measuring ICF -target burn history [ J] .Rev.Sci.In- strum.,1995 , 66 ( 1 ) : 933 -935 link1

Related Research